您的位置: 标准下载 » 协会标准 » ASME 美国机械工程师协会 »

ASME RP-2-2011 制造商的局部数据报告(I类).一家制造商为另一家制造商制造的纤维增强塑料压力容器部分

作者:标准资料网 时间:2024-05-06 22:17:46  浏览:9382   来源:标准资料网
下载地址: 点击此处下载
【英文标准名称】:Fabricator'sPartialDataReport(ClassI)-APartofaFiber-ReinforcedPlasticPressureVesselFabricatedbyoneManufacturerforanotherManufacturer
【原文标准名称】:制造商的局部数据报告(I类).一家制造商为另一家制造商制造的纤维增强塑料压力容器部分
【标准号】:ASMERP-2-2011
【标准状态】:现行
【国别】:美国
【发布日期】:2011-07
【实施或试行日期】:
【发布单位】:美国机械工程师协会(US-ASME)
【起草单位】:ASME
【标准类型】:()
【标准水平】:()
【中文主题词】:
【英文主题词】:Dataofthemanufacturer;Datasheets;Enterprises;Fibrereinforced;Productdata
【摘要】:
【中国标准分类号】:J74
【国际标准分类号】:23_020_30
【页数】:2P;A4
【正文语种】:英语


下载地址: 点击此处下载
Product Code:SAE J1832
Title:Low Pressure Gasoline Fuel Injector
Issuing Committee:Gasoline Fuel Injection Standards Committee
Scope: This SAE Recommended Practice promotes uniformity in the evaluation and qualification tests conducted on fuel injectors used in gasoline engine applications. Its scope is limited to electronically actuated fuel injection devices used in automotive port or throttle body fuel injection systems where fuel supply pressure is below 1000 kPa. It is primarily restricted to bench tests. More specifically, this document is intended for use as a guide to the following:Standardize use of nomenclature specifically related to fuel injectors.Identify and define those parameters that are used to measure fuel injector characteristics or performance. The parameters included in this document are listed along with their recommended symbol where appropriate:Closing Time (CT)Inductance (L)Coil Resistance (R)Dynamic Flow (Qd)Dynamic Flow Calculated (Qdc)Dynamic Flow Rate (Q)Dynamic Flow Temperature Shift (Qtd)Dynamic Flow Vacuum Shift (Qvd)Dynamic Minimum Operating Voltage (DMOV)Dynamic Set Point (PWxx)Dynamic Set Point Flow (Qsp)External LeakageFlow-Offset (Y)Insulation Resistance (IR)Linear Flow Range (LFR)Linearity Deviation (LD)Maximum Overload VoltageOpening Time (OT)Operating Voltage RangePeriod (P)Pulse Width (PW)Pressure Drop Ratio (PDR)RepeatabilitySlope (m)Slope Approximated (ma)Spray PatternStability (S)Static Drop-Out Current (I/S-OFF)Static Flow Rate (Qs)Static Minimum Operating Voltage (SMOV)Static Pull-In Current (I/S-ON)Time-Offset (X)Working Flow Range (WFR)Establish test procedures and recommend test equipment and methods to measure and quantify these parameters.Establish test procedures, and recommend test equipment and methods to quantify simulated field reliability over the life of the component.Except where stated, test results are recorded for individual parts under recommended test conditions. Where population characteristics are reported, the sample size, selection method, and analysis technique must be explicitly stated.Any testing practices which are different than those recommended in this specification should be noted on the data collection sheet.
Rationale: This SAE Recommended Practice promotes uniformity in the evaluation and qualification tests conducted on fuel injectors used in gasoline engine applications. Its scope is limited to electronically actuated fuel injection devices used in automotive port or throttle body fuel injection systems where fuel supply pressure is below 1000 kPa. It is primarily restricted to bench tests. More specifically, this document is intended for use as a guide to the following:Standardize use of nomenclature specifically related to fuel injectors.Identify and define those parameters that are used to measure fuel injector characteristics or performance. The parameters included in this document are listed along with their recommended symbol where appropriate:Closing Time (CT)Inductance (L)Coil Resistance (R)Dynamic Flow (Qd)Dynamic Flow Calculated (Qdc)Dynamic Flow Rate (Q)Dynamic Flow Temperature Shift (Qtd)Dynamic Flow Vacuum Shift (Qvd)Dynamic Minimum Operating Voltage (DMOV)Dynamic Set Point (PWxx)Dynamic Set Point Flow (Qsp)External LeakageFlow-Offset (Y)Insulation Resistance (IR)Linear Flow Range (LFR)Linearity Deviation (LD)Maximum Overload VoltageOpening Time (OT)Operating Voltage RangePeriod (P)Pulse Width (PW)Pressure Drop Ratio (PDR)RepeatabilitySlope (m)Slope Approximated (ma)Spray PatternStability (S)Static Drop-Out Current (I/S-OFF)Static Flow Rate (Qs)Static Minimum Operating Voltage (SMOV)Static Pull-In Current (I/S-ON)Time-Offset (X)Working Flow Range (WFR)Establish test procedures and recommend test equipment and methods to measure and quantify these parameters.Establish test procedures, and recommend test equipment and methods to quantify simulated field reliability over the life of the component.Except where stated, test results are recorded for individual parts under recommended test conditions. Where population characteristics are reported, the sample size, selection method, and analysis technique must be explicitly stated.Any testing practices which are different than those recommended in this specification should be noted on the data collection sheet.MIL-STD-2042/3B, DEPARTMENT OF DEFENSE STANDARD PRACTICE: FIBER OPTIC CABLE TOPOLOGY INSTALLATION, STANDARD METHODS FOR NAVAL SHIPS (CABLE PENETRATIONS) (PART 3 OF 7 PARTS) (25 JUL 2002)., This standard practice provides detailed methods of optical fiber cable penetrations through ship structure and equipment via stuffing tubes, swage tubes, multiple cable penetrators, chafing collars and nipples.